Tel:
China Backup Power Supply manufacturer
Xian Junbiao Electronics Technology Co.,Ltd.

RELIABLE & SECURE POWER SOLUTIONS

Home ProductsBackup Power Supply

12v 50ah 780WH 600W Ups Uninterruptible Power Supply Solar Power Generator

12v 50ah 780WH 600W Ups Uninterruptible Power Supply Solar Power Generator

    • 12v 50ah 780WH 600W Ups Uninterruptible Power Supply Solar Power Generator
    • 12v 50ah 780WH 600W Ups Uninterruptible Power Supply Solar Power Generator
    • 12v 50ah 780WH 600W Ups Uninterruptible Power Supply Solar Power Generator
    • 12v 50ah 780WH 600W Ups Uninterruptible Power Supply Solar Power Generator
  • 12v 50ah 780WH 600W Ups Uninterruptible Power Supply Solar Power Generator

    Product Details:

    Place of Origin: CHINA
    Brand Name: J-ENERGIZE
    Model Number: YY600+

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 unit
    Packaging Details: Carton
    Delivery Time: negotiable
    Contact Now
    Detailed Product Description
    Rated Capacity: 600W Input Voltage: (85V-135V)/(165-275)VAC
    Application: Home,Commercial,Instrumentation,home & Outdoor,Fans BATTERY*: Gel-780WH
    BATTERY RATED VOLTAGE: 12/24VDC OUTPUT VOLTAGE: AC110V/120V//220V/230V±2%
    High Light:

    780WH Ups Uninterruptible Power Supply

    ,

    600W Ups Uninterruptible Power Supply

    ,

    12VDC Solar Generator Kit

    YY SERIES

    PORTABLE SOLAR GENERATOR KIT

    12v 50ah 780WH 600W Ups Uninterruptible Power Supply Solar Power Generator

    1. Technical parameter

    Model YY600+ YY1000+ YY1500+ YY2000+ YY2400+
    Rated power 600W 1000W 1500W 2000W 2400W
    DC Input voltage 10.5-15V 20-29V 20-29V 40-55V 40-55V
    AC Input voltage (165-275)VAC
    AC Input Frequency 45-65Hz
    AC Output voltage AC220V±2%(BATTERY MODE)
    AC Output Frequency 50/60HZ±1%(BATTERY MODE)
    DC Output voltage 2*DC 5V/1A 2*DC 5V/2.1A 1*12V/10A 1*12V/20A (BATTERY MODE)
    Output waveform Pure sine wave
    Efficiency 85%
    Transfer time 4ms
    Battery LiFePo4
    Battery capacity 12v50ah 24V20AH 48V26AH 48V26AH 48v26ah
    Max AC Charge current 0-40A(Optional)
    AC Charge time 5H 6H 8H 10H 12H
    Solar input voltage

    PWM (12V TO 25V, 24V TO 50V, 48V TO 80V)

    MPPT (12/24/48V TO 72V/150V)

    Solar charge current 40A
    Solar panel * 150W 150W*2 200*2W 280W*2 330W*2
    Solar panel charge time 6H 7H 7H 8H 8
    Protection Over voltage, over term, over load, short circuit, battery voltage high & low,AC input voltage high & low, automatic re-cover
    Overload capacity 110-125%,turn to by pass after 60 secs,over 125% maintain 10 secs and then shut down
    Communication interface RS-232/USB (Optional)
    Operation term -25~55°C
    Humidity 5%~90%( non-condensation)
    Noise ≤ 45dB (with in 1 Meter)
    Altitude ≤ 4500m
    Cooling Air cooling(inner term over 45°C) when machine temperature is up to 45℃, fan works; when it’s lower than 45℃, fan stop automatically.
    MTBF 50000H
    Dimension L380*W195*H380mm
    Package dimension L470*W280*H420mm
    Net weight 11kg 11.5kg 15kg 26kg 29kg
    Gross weight 14kg 14kg 16kg 26kg 29kg
    *Customizable battery capacity and battery type(Lithium,VRLA)

     

     

     

    2. Appearance

    1KW-3KW series

    12v 50ah 780WH 600W Ups Uninterruptible Power Supply Solar Power Generator 0

    3. Installation Instruction

    3-1.Open up

    After opening the package, please check the accessories, including 1 pc of user manual. And please make sure that the inverter is well-protected after transportation, if any damage:

     

    Note: component miss, do not turn on the machine, feedback to the carrier and distributor.

     

    1). Please retain the packing material, those can be used for next delivery if needed.

    2). This series of products is heavy (check attachment as reference), please handle carefully when carrying.

    3-2. Installation notice

     

    1). Install in an area of well-ventilated, free of water, burning gas and corrosive stuff.

     

    2). Not good to stand on sides, should keep good air inlet from front panel’s bottom and side face of machine, air outlet from back panel’s fan.

     

    3). Environment temperature should remain from 0 to 40 centigrade.

     

    4). When disassembling and operating under low temperature, it may cause water condense, should not turn on until sides of machine being dry, or it will be shock risk.

     

    5). Install the inverter near mains socket or switch, in order to pull out mains supply plug to cut off power easily when meeting emergency.

     

    Attention:

    < Loading should be turned off before connecting to inverter and turned on the loading one by one after connection completed.

    < Connect inverter to accessible socket with over-current protection.

    < All power sockets should link with ground protection.

    < Inverter may have electricity whether input power cable inserts to mains socket or not. Turning off the inverter does not guarantee electricity does not exist. To ensure no output, should turn off all switches and cut the mains power.

    < To load inductive appliances such as electromotor, displayer and laser printer, inverter capacity should be two times compared to rated power of the load.

     

     

    4. Description of panel

    Detail of LCD

    1 Input Voltage 2 Working Mode 3 Output Voltage

    4 Solar Panel 5 Battery Status 6 Loading Application

    7 Silent Mode 8 Loading Status

    12v 50ah 780WH 600W Ups Uninterruptible Power Supply Solar Power Generator 1

    Detail of indicate lamp & button

     

    INPUT AC input voltage
    Hz output frequency / Working mode
    OUTPUT AC output voltage
    BATT. CAPACITY Battery working condition and capacity
    LOAD Load power
    NORMAL AC input at normal status
    FAULT False signal light
    BATTERY Battery mode
    25%--100% Overload condition
      ENTER
      ON/OFF
      UP
      DOWN
     

    5. Function and setting

    ON/OFF Button: Press for 3 seconds to turn on and 5 seconds turn off.

    ENTER Button: Press for 5 seconds start to set Mode P0 to P4. Switch through UP & DOWN button.

    Mode P0- Pre-set. Press ENTER 2 times to end up setting. Auto Exit after 10 seconds' no-ops.

    Mode P1- Power supply setting. 01- AC supply in priority, 02- Energy saving. 03- Battery supply in priority, switch through UP & DOWN and select through ENTER button.

    Mode P2- Battery Type setting. Switch through UP & DOWN and select battery type through ENTER button.

    Mode P3- Charging Current 0-35A selecting. 0-20%-40%-60%-80%-100%, Maximum is 35A, Minimum 0A.

    Mode P4- Voice setting. Switch the Buzzer through UP & DOWN and select through ENTER button.

     

    Position Float(V) Position Float(V)
    U0=Gel U.S.A 13.7V U4=Gel European 13.8V
    U1=A.G .M.1 13.4V U5=Open lead acid 13.8V
    U2=A.G .M.2 13.7V U6=Calcium (open) 13.6V
    U3=Sealed lead Acid 13.6V    

     

     

     

     

    12v 50ah 780WH 600W Ups Uninterruptible Power Supply Solar Power Generator 2

     

     

     

    6. Connection

    Attention:

    Terminal and output plug are both available to connect the load. Output plug can only allow the loading under 1500W. Loading over 1500W should connect to terminal.

    Solar wiring diagram

    12v 50ah 780WH 600W Ups Uninterruptible Power Supply Solar Power Generator 3

     

    Note:

     

    If connect to generator, must follow the steps below:

     

    • Start generator, after it go stably, connect its output port to inverter’s input port (to be sure there isn’t any load connecting to inverter at this moment).
    • Start the inverter, connect the loads one by one.
    • Choose generator with 2 or 3 times capacity compared to inverter.
    • Solar inverter’s panel and connection is different from common model.
    • The voltage of solar panel should follow the Technical parameter.

     

    Back panel connection

    BATTERY Negative Battery negative polarity connection
    BATTERY Positive Battery positive polarity connection
    AC INPUT AC input connection
    AC OUTPUT Universal socket output or terminal output
    FUSE AC INPUT Ac input voltage over current protection
    FUSE AC OUTPUT Ac output voltage over current protection
     

     

     

    Note:

     

    If connect to generator, must follow the steps below:

     

    • Start generator, after it go stably, connect its output port to inverter’s input port (to be sure there isn’t any load connecting to inverter at this moment).
    • Start the inverter, connect the loads one by one.
    • Choose generator with 2 or 3 times capacity compared to inverter.
    • Solar inverter’s panel and connection is different from common model.
    • The voltage of solar panel should follow the Technical parameter.

    7. Care and maintenance

    This series of inverter fairly needs maintenance. Turn to battery charge mode to extend the life of battery.

     

    discharge and charge the batteries at least 1 time every 6 months. Charging time should not be less than 12 hours.

    In high temperature area, battery should be charged and discharged every 2 months and standard charging time is not less than 12 hours.

    Basically batteries works 3-5 years, should replace when working not well.

     

    Ask professionals to replace the batteries.

     

     

    Note:

     

    • Before replacing battery, must switch off battery, inverter and mains supply.
    • Put off the metal object like ring, watch etc.
    • Use insulated tool and avoid putting any tool and metal object on battery.
    • When connecting battery, it may strike some un-harmful sparks.
    • Do not make converse connection.

    8. Solution for difficult situation

     

    False Cause Solution
    No city power input Recoverable fuse popup Press fuse back
    Terminal heating Fault or loose connection Reconnect
    Auto switch off with loads Battery no power or overload Charge battery or reduce loads
    Switch on failure Fault connection with city power or battery Check connection with battery or reconnect
    Alarm when switch on Battery no energy or overload Charge battery or reduce loads
    Buzzer screams 2 secs every 3 secs Over temperature alarm (85℃-alarm,90℃-shut down) Check if fan or vents jammed
    Fan’s speed not stable Smart control according to temperature Leave it
     

     

    Contact Details
    Xian Junbiao Electronics Technology Co.,Ltd.

    Contact Person: Arms Wang

    Send your inquiry directly to us
    Other Products
    Xian Junbiao Electronics Technology Co.,Ltd.
    996 TianGu Qi Road, Xi'an, Shaanxi, P.R.China
    Tel:86-029-65659372
    Mobile Site Privacy Policy China Good Quality Backup Power Supply Supplier. © 2020 - 2021 backup-powersupply.com. All Rights Reserved.